Data Logger
|
Channels
|
Measurement Range
|
Resolution
|
Max. Readings
|
Temperature: Thermistor |
SmartReader 1 |
2
|
-60 to 255 ºC (-76 to 491 ºF) |
8
|
32767
|
SmartReader 8 |
8
|
-60 to 255 ºC (-76 to 491 ºF) |
8
|
N/A
|
SmartReader Plus 1 |
2
|
-60 to 255 ºC (-76 to 491 ºF) |
12
|
1048000
|
SmartReader Plus 8 |
8
|
-60 to 255 ºC (-76 to 491 ºF) |
12
|
1048000
|
OWL 100 |
1
|
-40 to 70 ºC (-40 to 158 ºF) |
8
|
32767
|
OWL 200 |
1
|
-40 to 70 ºC (-40 to 158 ºF) |
8
|
32767
|
JR-1000 |
1
|
-40 to 85 ºC (-40 to 185 ºF) |
7
|
32767
|
JR-1001 |
1
|
-40 to 85 ºC (-40 to 185 ºF) |
8
|
32767
|
SmartButton |
1
|
-40 to 85 ºC (-40 to 185 ºF) |
8
|
2048
|
Temperature: Thermocouple |
SmartReader 5 |
3
|
J, K, S, T thermocouple ranges |
8
|
32767
|
SmartReader 6 |
7
|
J, K, S, T thermocouple ranges |
8
|
32767
|
SmartReader Plus 5 |
3
|
E, J, K, S, T thermocouple ranges |
12
|
87000
|
SmartReader Plus 6 |
8
|
E, J, K, S, T thermocouple ranges |
12
|
1048000
|
Temperature: RTD |
SmartReader Plus 10 |
4
|
-230 to 300 ºC (-385 to 572 ºF) |
12
|
87000
|
Temperature: Waterproof |
Nautilus85 |
1
|
-40 to 85 ºC (-40 to 185 ºF) |
4
|
244800
|
Nautilus135 |
1
|
10 to 135 ºC (50 to 275 ºF) |
8
|
244800
|
Relative Humidity |
SmartReader 2 |
4
|
-40 to 70 ºC (-40 to 158 ºF), 0-95% RH |
8
|
32767
|
SmartReader Plus 2 |
4
|
-40 to 70 ºC (-40 to 158 ºF), 0 to 95% RH |
12
|
87000
|
TRH 1000 |
2
|
-40 to 70 ºC (-40 to 158 ºF) & 0-100% RH |
8
|
65000
|
Electrical: Current & Voltage |
SmartReader 3 |
4
|
50 or 60 Hz, 5 to 500 A (3000 A CT also available) |
8
|
32767
|
SmartReader Plus 3 |
8
|
5 to 500 A (3000 A CT also available),
120 Vac or 480 Vac |
12
|
104800
|
OWL 300 |
1
|
5, 25, 100, 250A or 10, 50, 250, 500A
(3000A CT also available) |
8
|
32767
|
Electrical: Power Quality |
PowerWatch 120V |
1
|
100-120 Volt, Single Phase |
N/A
|
4000
|
PowerWatch 220/240V |
1
|
220-240 Volt, Single Phase |
N/A
|
4000
|
Electrical: Pulse & Switch Contact |
SmartReader 9 |
3
|
256 pulse/sample rate max. |
8
|
32767
|
SmartReader Plus 9 |
4
|
4095 pulse/sample rate max. |
12
|
87000
|
Pressure |
SmartReader 4 |
5
|
0 to 5, 30, 100, 150 psi |
8
|
32767
|
SmartReader Plus 4 |
4
|
0 to 5, 30, 100, 150 psi & 10" WC |
12
|
87000
|
SmartReader Plus 4 LPD |
2
|
±0.5, 1, 2, 5, 10" WC |
12
|
21500
|
Process Signal |
SmartReader 7 |
8
|
2.5v, 5v, 10v, 25mA, 200mV |
8
|
32767
|
SmartReader Plus 7 |
8
|
2.5v, 5v, 10v, 25mA, 200mV |
12
|
104800
|
OWL 400 |
1
|
0-38.4 Vdc max. |
8
|
32767
|
OWL 500 |
1
|
0-24 mA dc |
8
|
32767
|
Carbon Dioxide & Other Gases |
IAQ Logger |
5
|
-40 to 70 ºC (-40 to 158 ºF) & 0-95% RH;
0-4000 ppm CO2 |
8
|
32767
|